Our activities are focused on digital cameras test charts and scanners targets.
We produce wide assortment of both transmissive and reflective charts for measuring
limiting resolution / MTF opto-electronic conversion function / dynamic range colour rendition / ICC profiling
Actual measured data: Many of our test charts come together with actual measured data. Density, Transmission/Reflection coefficients, Lightness, RGB levels, spectral curves. Our camera test charts are only rarely glossy. Even 160:1 luminance ratio charts are easy to glareless illuminate.
Our assortment is rapidly changing according to our client´s needs. Please, ask us for our actual size, material and precision possibilities.
|
|
DIGITAL STILL CAMERAS test charts |
|
|
|
ISO / i3a (PIMA) test charts |
|
|
|
DCR3 ISO 12233 test chart for resolution measurement, in 20 versions. Sizes: 20x36 mm to 0,8x1,4m. Matt, semimatt, semiglossy, glossy, transmissive. Actual assortment in our price-list. |
DCR4 Enhanced ISO 12233 test chart (up to 4000 pph). Sizes: 20x36 cm to 0,8x1,4m. Matt, semimatt, semiglossy, glossy, transmissive. Actual assortment in our price-list. |
|
|
|
|
DCU1 ISO 15739 test chart for noise measurement, in various versions. Sizes 10x18 cm to 0,8x1,4m. Semiglossy, glossy, transmissive. Luminance ratios (contrasts): 20:1 to 160:1. Actual assortment in our price-list. |
DCG2 ISO 14542 test chart for OECF measurement, in various versions. Sizes 10x18 cm to 0,8x1,4m. Matt, semimatt, semiglossy, glossy, transmissive. Luminance ratios (contrasts): 20:1 to 1000:1. Actual assortment in our price-list. |
|
|
DCU4 ISO 15739 test chart, in various versions. Sizes 10x18 cm to 0,8x1,4m. Semiglossy, glossy, transmissive. Actual assortment in our price-list. |
IEEE, IEC, SMPTE, EIA, ITE, EIAJ, ... Charts for still / video / cine cameras. Charts are produced by request. |
|
|
other monochrome camera charts |
|
|
|
DCR1 Reflective chart 21x30 cm (A4), on matt silver photopaper. Cheap chart for complete camera resolution check in optimal object distance. |
DCR2 Reflective chart 6x20 cm, offset printed. Very cheap chart for rough camera image quality check in optimal object distance. |
|
|
GC18 Grey card, matt surface, perfect neutrality, 18% reflectancy. 1mm thick cardboard chart. Available in 2 sizes: GC18 = 8"x10" (cca 20x25,5cm), GC18s = 4"x5" (cca 10x12,5cm). |
GC1890 Grey/white card, matt surface, perfect neutrality, 18% grey on front side, 90% white on back reverse. 2mm thick cardboard chart. Available in 2 sizes: GC1890 = 8"x10" (cca 20x25,5cm), GC1890s = 4"x5" (cca 10x12,5cm). |
|
|
|
|
ST13 20 steps, 10x22,5mm each, silk-screen printed, semiglossy. Chart size 60x203 mm. Densities: min=0,05, max=1,95, progression 0,1 D, contrast 80:1. The chart can be used with IMATEST software (www.imatest.com) Actual measured data by request. |
GC3 Grey card with 3 matt patches Reflectancies: 90% white, 18% grey and 1% black . Size 60x203mm, 1mm thick cardboard chart. Photoshop application : for setting up white-grey-black levels using eyedropper. Your RGB gamma values and grey balance will be set in tree clicks. Available also in lower contrast versions. |
|
|
|
|
TS30D (transmissive) 10mm high cutting of grey step wedge. 30 steps, 6x10mm each. Strip size 10x230 mm. Densities: Dmin=0,08, step1=0,15, step30=3,05, progression=0,10. Contrast 1000:1. When putted on a lightbox and photographed, the grey strip enabled measurement of opto-electronic conversion function (OECF) and dynamic range of the camera. Actual measured data are based on opal diffuse densities (the strip is manufactured on silver film): D, T, L*, sRGBgrey. |
OW20S 20 steps, 9,5x16mm each, silk-screen printed, semiglossy. Chart size 45x190,5 mm. Densities: min=0,05, max=1,95, progression 0,1 D, contrast 80:1. The chart can be used with IMATEST software (www.imatest.com) Actual measured data by request. |
|
|
colour camera charts |
|
|
|
BST4(new) Colour Rendition Chart with CD. CD contains: Instructions, L*a*b* batch data for 5 common RGB spaces (sRGB, Abobe 1998, Apple RGB, Color Match, Wide Gamut) with comparator (Excel file) to check colour rendition and to find optimal RGB space for your camera, digital versions of the chart in sRGB and Adobe 1998 spaces, reference data for IMATEST application, RGB values for 5 photo and 2 video colour spaces (incl.vectorscope coordinates) and data for ICC profiling. 3 types available: reflective 234x334mm, reflective 406x584mm. Transmissive chart 180x240mm by request. |
BST11 Colour chart with reference data on CD. Compatible with ICC profiling softwares and IMATEST.
Available in 4 sizes: Reflective: 14x19 cm, 20.3x29.2 cm, 40.6x58.4 cm. Transmissive: 29x32 cm. |
|
|
|
|
DCU3 Semiglossy print with precise resolution patterns, either sticked on massive board, or rolled in tube. Size 40x71 cm (reflective only). For camera overall check (16:9). |
BST12 Semiglossy colour chart with reference data on CD. Compatible with ICC profiling softwares.
Available in 3 sizes (reflective only): 11.5x17 cm, 20.3x29.2 cm, 40.6x58.4 cm.
|
|
|
SCANNERS test targets |
|
|
|
IT8 test targets for scanners characterisation Our IT8´s are exposed mostly on Kodak photo materials (Ektachrome, Ektacolor). Charts on other paper/film stocks on demand (Fuji, Agfa, Konica).
Charts are measured by calibrated spectrophotometer Gretag Spectrolino. Average batch colorimetric data (XYZ, L*a*b*) are available for each production batch.
|
|
|
|
IT8.7/1 Transmissive Target 4"x5" Exposed on Ektachrome Professional film. Format type : Uni. |
IT8.7/2 Reflective Target Exposed on Kodak Endura photopaper. Format types: Kodak, Fuji. Available in 2 sizes: 5"x7" (glossy), A4 (semimatt) |
Downloads of batch colorimetric data
All data are in standardized ANSII format (*.txt files). Please, download data type you need (for either Transmissive or Reflective targets). Unzip downloaded archive. Use respective *.txt file (according to Batch No. of your IT8 Input Target) and create individual ICC profile of your scanner. |
Download here transmissive data |
|
|
Available sizes: transmissive 35mm, transmissive 4"x5", reflective 5"x7", reflective A4.
Available types (three types of right hand columns): Kodak, Fuji, Agfa.
There are only two products on stock: reflective chart 5"x7" Kodak type glossy and reflective chart A4 Kodak type semimatt. Please, ask us about availability of transmissive charts.
We manufacture for you other types and sizes by request. |
|
scanner resolution test targets |
|
|
|
FSR1 For 35mm microfilm / film / reflective scanners. 28x42 mm pattern, on 35mm strip of high resolution photo material. For visual evaluation of scanner resolution. 31 groups of ISO2 patterns with resolution 12,5 to 250 line pairs per millimeter (cycles/mm). 2 versions are available: Transmissive (FSR1T) and reflective (FSR1R, on opaque white base film). |
FSR2 For film / reflective scanners. 6x9 cm chart on high resolution sheet photo material. For numerical evaluation of spatial frequency response (SFR) of scanners. 13 groups of special SFR-patterns in 4 directions, with logarithmic progression. Resolution 2 to 160 cycles / millimeter (corresponds to resolution 100 to 8000 dpi). 2 versions are available: Transmissive (FSR2T) and reflective (FSR2R, on opaque white base film). |
|
|
GEO3 Reflective
chart for testing geometric quality of digitized images. The chart is A4 sized, with thin (0,1 mm) paralell lines in 2 directions. Line distance is 5mm. |
OTHER ISO, USAF, ... CHARTS Charts are produced by request. |
|
|
scanner grey step test targets |
|
|
|
|
|
OW20SDG 20 steps, 9,5x16mm each, silk-screen printed, glossy lamination. Wedge size 44,5x190,5 mm. Densities: min=0,10, max=2,20, progression cca 0,1 D, contrast 120:1. Actual measured data: D, T, L*, sRGBgrey. |
TS28D (transmissive) Calibrated strip for film scanners. 10mm high cutting of grey wedge. 28 steps, 7x10mm each. Overall size 10x230 mm. Densities: min 0,15, max 4,20, progression 0,15, contrast 12000:1. Actual measured data are based on opal diffuse densities ( the strip is manufactured on silver film): D, T, L*, sRGBgrey. |
|